Protection Circuit Module For 16 Cells LiFePO4 Battery Pack 30A
Protection Circuit Module For 16 Cells LiFePO4 Battery Pack 30A
Protection Circuit Module For 16 Cells
Usage and Attention:
- After purchasing the protection mould, users should connect lines
in compliance with the instruction. Voltage usually exists in the
battery, so operators should peel one line and then connect another
starting from B-. Lines should be connected from the low position to
the high position with no mistake of order, or the irreparable damage
could be caused.
- When lines get connected, bits of copper and tin should not cling to the guard shield.
- Protection board should be connected to battery group with
compliance to specifications and any leading line should not be put on
the back of the board but on the lateral side.
- When equipping the guard shield, hard epoxy sheer should be fixed
on the back of the board as the barrier to prevent the squeezing
against short circuit.
- When welding output lines, power supply line with the proper
diameter should be chosen to prevent great temperature rising and great
dropping of line voltage while high current discharges.
- The guard shield is usually fixed in the battery box, insulation,
heat relief and tightness should be greatly concerned, or the internal
short circuit could lead to some danger.
- The full-charged battery group should be put properly out of children’s touch.
- If any unusual condition appears during the using process, please stop using the product immediately.
Main Functions:
The product has 5 main functions: over charge, over discharge, over current, short circuits and balancing.
- Function of over charge protection: once voltage of any battery
in the group gets higher than the over charge protection point, charge
cuts off to ensure all batteries work within the over charge protection
point.
- Function of over discharge: once voltage of any battery in the
group gets lower than the over charge protection point, discharge cuts
off to ensure all batteries work beyond the over charge protection
point.
- Function of over current: during the discharge process of battery
group, once discharge current gets over the set over current
protection point, output cuts off to ensure battery group works within
the safe limit of current.
- Function of short circuit protection: once battery group’s output
port appears the condition of short circuit, it cuts off to ensure
battery group not to be damaged because of short circuit.
- Function of voltage balancing: in the late charging period of
battery group, voltage difference that appears during the using process
of each battery could get balancing revised to ensure battery group’s
capacitance.