Features
* Applies to 8 cells Li-ion/Li-polymer battery pack protection* Internally Trimmed Charge and Discharge Voltage Limits
* Discharge Current Limit Detection
* High Quality and High Yield100% Tested before Shipment Working Voltage29.6VMaximal Working current15ADimension115mm x 80mm x 15mmWeight58g Electric PerformanceNo. Items Min Typ Max Unit 1 Charging voltage 33.76 34 V 2 Charging current 15 A 3 Discharging current 12 15 A 4 Current consumption 300 uA 5 Balance current for single cell 55 60 65 mA 6 Blance voltage for single cell 4.18 4.2 4.22 V 7 Overcharge detection voltage for single cell 4.3 4.325 4.35 V 8 Overcharge detection delay time 0.96 1.2 1.4 s 9 Overdischarge detection voltage for single cell 2.4 2.5 2.6 V 10 Overdischarge detection delay time 115 144 173 ms 11 Short circuit protection Exterior short circuit 12 Protection circuitry resistance 15 30 mΩ 13 Operating Temperature Range -40 85 C 14 Storage Temperature Range -40 125 C
Working Voltage: 29.6V
Maximal Working current: 15A
Dimension: 115mm x 80mm x 15mm
Weight: 58g
Electric Performance: | |||||
No. | Items | Min | Typ | Max | Unit |
1 | Charging voltage | 33.76 | 34 | V | |
2 | Charging current | 15 | A | ||
3 | Discharging current | 12 | 15 | A | |
4 | Current consumption | 300 | uA | ||
5 | Balance current for single cell | 55 | 60 | 65 | mA |
6 | Blance voltage for single cell | 4.18 | 4.2 | 4.22 | V |
7 | Overcharge detection voltage for single cell | 4.3 | 4.325 | 4.35 | V |
8 | Overcharge detection delay time | 0.96 | 1.2 | 1.4 | s |
9 | Overdischarge detection voltage for single cell | 2.4 | 2.5 | 2.6 | V |
10 | Overdischarge detection delay time | 115 | 144 | 173 | ms |
11 | Short circuit protection | Exterior short circuit | |||
12 | Protection circuitry resistance | 15 | 30 | mΩ | |
13 | Operating Temperature Range | -40 | 85 | C | |
14 | Storage Temperature Range | -40 | 125 | C |